Generators, Single Phase Generators, Three Phase GeneratorsJET MASTER generator range is the registered generator range from United power corporation. Owning a generator is no more longer a "nice to have", fast development and growth lead to many Grid power failures. Generators it is fast becoming a standard part of your house hold requirements. We offer a wide range of petrol generators and diesel generators , both single phase generator and three phase generators. The units is either portable or can be fitted for a fixed panel appliances. The new range of silent generators fit well into the portable and mobile markets. We can arrange installation of a generator at your premises with pre-wired switch-over boards. Please refer to our section on generator advice to help you choose your generator!!
CHOOSING THE BEST GENERATOR FOR THE JOBThese are the things to consider when selecting a generator: HOW DO YOU PLAN TO USE YOUR GENERATOR?Generators are used to perform a wide variety of tasks, our generators provide a high quality power source that is reliable and convenient.
HOW QUIET DOES YOUR GENERATOR NEED TO BE?Our generators are known for quiet operation. JET MASTER engineered exceptionally quiet portable models, but offers less costly options that may serve your application at a lower cost. While a camping application may require a super quiet EU series choice, home standby and construction applications would be satisfied with a deluxe or industrial series model, and some applications will allow for the Economy series that do not have the additional features required to provide quiet operation. IS ELECTRIC START REQUIRED?Jet Master generators are renown for the ease of starting, even when only equipped with a manual recoil starter. We offers many models with the convenience of electric start for applications that may require remote start or where the ease of electric start is preferred. DO YOU REQUIRE EASY TRANSPORT?While all Generators are Portable by definition, many models include standard wheel kits for easy movement of the generator from storage to the work site. Consider the options when selecting the right model for your application. HOW MUCH POWER DO YOU NEED?Generators produce AC voltage, very similar to the voltage available in your home, however while your electric utility company produces sufficient power for all your electric powered devices, a portable generator is limited in power output directly relational to the engine horsepower. The amount of power that a generator can produce is rated in watts. Rated power is generally 90% of maximum power as certain components lose efficiency as they are heated from use. To determine wattage requirements you should determine which devices need to be powered simultaneously and what the starting requirement of the device is. Remember that with simple "Power Management" techniques, a small generator can provide adequate power for home or recreational applications. “MAXIMUM” AND “RATED” POWERA generator should never be operated at its MAXIMUM power output for more than 30 minutes. RATED power, or the power that a generator can produce for long periods of time, is a more reliable measure of generator power. Typically the RATED power is 90% of the MAXIMUM power. For Example, a 2500 watt generator produces a MAXIMUM 2500 watts of power. This means at maximum power this generator could light up 25 100-watt light bulbs at the same time. The rated wattage of this generator would be 2300 watts and should only be used to power 23 - 100 watt light bulbs. When considering your power needs, first determine the highest power application such as a well pump for home power or air compressor for the job site. The power required to start the capacitor motor on these applications will determine the rated power of the generator you should choose for your application. TYPES OF LOADSIn the previous example, the light bulbs are the LOAD of the generator. A 2500 watt generator can handle a LOAD of no more than 2500 watts maximum. RESISTIVE LOADS: The light bulb example is called a RESISTIVE type load and the POWER it requires is pretty easy to understand. Other RESISTIVE types of LOAD are things like toasters, convection ovens, hot plates, curling irons, coffee makers, stereos and TV's. RESISTIVE LOADS are usually appliances that do not have electric motors. A REACTIVE load contains an electric motor. Some household appliances like a furnace or refrigerator have internal fans that come on intermittently, so extra wattage/power is needed to start the fan. Another example is power tools. An appliance or tool with a reactive load may require up to three times as much power (wattage) to START as it does to keep it running. Examples of REACTIVE type loads: • Refrigerators / freezers REACTIVE LOADS = 3 x Power RESISTIVE LOADS:The equation shows the relationship between watts, volts and amps in a PURELY RESISTIVE load. If you know any of the two variables, the third can be calculated. Example: You want a generator to power a 1000 watt flood light. The light is 120V and requires 1000 watts of power. Using the equation, we can calculate that the floodlight will draw 8.3 amps of electrical current. For REACTIVE loads, the equation shows only a general relationship between watts, volts and amps. That's because the power requirements for REACTIVE loads changes with operating conditions. Resistive Loads – Volts x Amps = Watts REACTIVE LOADS:When determining the proper generator for REACTIVE type loads, you must consider three modes of operation: STARTING - The electric motor requires more power to start. The starting power required can be up to THREE times the running amount. RUNNING - The power required to run the electric motor once it has been started. LOADED - When the electric motor begins to work (saw begins cutting wood, drill begins drilling thru a wall), its power requirement will increase. This is not applicable for most household appliances. DATA TAG:Method 2 requires a visual inspection of the data tag supplied by the electric motor manufacturer. All electrical motors have a data tag attached to their bodies that give volts, amps, phase, cycles, hp, and sometimes a code. Volts (V) - The volts must be either 120 (110-120) or 120/240. 120/240 means that the motor can be wired to operate on 120V or 240V. Generator summary Diesel generators, Petrol generators, single phase generators , Three phase generators, Silent generator (Petrol or Diesel), generators, generator, Generator, Generators
|
||||||||||||||||||||||||
|
||||||||||||||||||||||||
Copyright © Plan-My-Power (PTY) ltd | website by cantaloupe |
||||||||||||||||||||||||